MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Con
fi
guring Redundant Site Controller
Procedure 15-5
How to Add Redundant Site Controller (Continued)
10
Connect the redundant control signal cable according to the scheme below:
Part no
Cable type
From
To
3066544B17
Redundant
CTRL signal
cable
SC1 / RedIn
SC2 / RedOut
3066544B17
Redundant
CTRL signal
cable
SC1 / RedOut
SC2 / RedIn
Make sure to follow the color indications on both the cables as well as on the Site
CONTROLLER.
11
Remove the Terminator from the CAN2 output on the Power Supply Unit and connect the CAN
Bus cable according to the scheme below:
Part no
Cable type
From
To
3066544B03
CAN Bus cable
SC2 / CAN
PSU2 / CAN2
12
Connect the power cables to the MTS Power Supply Units.
Configuring Redundant Site Controller
Redundant Site Controller feature is supported by MTS Software releases:
•
MTS SPU R5.2_002.34 or later
•
MTS SPU R6.0_001.12 or later
On power up of the Standby Site Controller the Base Radios may dekey and reset. Base
Radios will automatically recover and key up again within 20 seconds.
6802800U74-N September 2009
15-29
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...