MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
PSU Connectors
Table 11-3
Power Supply Unit Connectors (Continued)
Name of
Connector
Type
To/From
Comment
Battery
Temp. Sens.
MOLEX (2 pin)
Junction Panel
Connection with the backup
battery temperature sensor
ATCC Out
MOLEX (2 pin)
ATCC
DC power supply for ATCC
MOLEX (14 pin)
2 Base Radios and Site
Controller
Pin 1 - 3
GND
Pin 8
+7 V
Pin 10 - 11
+28.5 V
Base Radio
Pin 4 - 6
GND
Pin 9
+7 V
Pin 12 - 13
+28.5 V
Base Radio
Pin 7
GND
DC Out
Pin 14
+28.5 V
Site Controller
DC power supply
MOLEX (4 pin, male)
Pin 1
+Vfan
Pin 1
-Vfan
Pin 1
-Vfan
Fan 1
Pin 1
Alarm
Fan 1
DC supply for Fan 1
MOLEX (4 pin, male)
Pin 1
+Vfan
Pin 1
-Vfan
Pin 1
-Vfan
Fan 2
Pin 1
Alarm
Fan 2
DC supply for Fan 2
MOLEX (4 pin, male)
Pin 1
+Vfan
Pin 1
-Vfan
Pin 1
-Vfan
Fan 3
Pin 1
Alarm
Fan 3
DC supply for Fan 3
6802800U74-N September 2009
11-9
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...