MTS - Con
fi
guring E1 Links
Chapter 8: Site Controller
MTS - Configuring E1 Links
Syntax for
.e1con
fi
g
MMI command:.
.e1config [-portNo -link -crc -ts16Skip -clock -siteLink -channel
-tsPattern -DI -sat -display -?]
•
-portNo = assign physical E1 port to channel
•
-link = con
fi
gure options related to physical E1 line/interface
•
-crc = enable/disable CRC4
•
-ts16Skip = use/not use E1 16-th time slot
•
-clock = select Clock source
•
-siteLink single|dual = select single E1 or dual E1 sitelink con
fi
guration
•
-channel = creates and con
fi
gures Logical E1 circuit by assigning single or
multiple E1 timeslots to a particular physical E1 port
•
-tsPattern 1..31 = assign time slots to a proper channel
•
-DI on|off = turn of/off Drop & Insert functionality. Is always off for star con
fi
guration,
but must be enabled for ring/chain con
fi
gurations
•
-sat on|off = set link as satellite one
•
-display 1|2|all = display E1 con
fi
guration
•
-? = display help for this command
Table 8-9
Slots Configured on the E1
No. of BR's in Site
Slots Configured on the E1
1
1
2
2
3
2
4
3
5
3
6
4
7
4
8
5
8-28
6802800U74-N September 2009
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...