Expansion Cabinet Power-Up
Chapter 4: Hardware Installation
Procedure 4-16
How to Power-Up MTS and Expansion Cabinet (Continued)
•
Output and temperature indicator (DC OUT / TEMP):
◦
Green LED when DC output voltages are present and within limits
◦
Red LED when one or more of the output voltages failed
◦
Red LED
fl
ashes when over temperature is detected, 5 -10 °C before shutdown
•
AC input indicator (AC IN STATUS):
◦
Green LED when AC input voltage is present and within limits
◦
Red LED when AC input voltage is not present or out of limits
•
DC input and charging indicator (DC IN STATUS):
◦
Green LED when PSU is supplied from DC input
◦
Amber LED (green/red) when battery is charged
◦
Red-green
fl
ashing LED when a backup battery or a DC source supplies the PSU
and the source voltage drops below 43 VDC ±3%
◦
Red LED when no source connected to the DC input or the DC voltage is below
40.5 V
4
Using a digital voltmeter (DVM), verify a voltage level between -44 VDC and -60 VDC at the
“-48 VDC”- (hot) terminal and “Return”- terminal of the Power Supply Unit.
The Power Supply Unit automatically recognizes a connected backup battery and
begins charging, no matter if in operation or at start up.
4-64
6802800U74-N September 2009
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...