guring Redundant Site Controller
Chapter 8: Site Controller
Remember to check the con
fi
guration of both Site Controllers.
In order for the Redundant Site Controller feature to work correctly, the Ethernet ports used
to connect the two Site Controllers need to be speci
fi
cally con
fi
gured. The correct IP address
for each Site Controller must be as speci
fi
ed below.
Site Controller 1 (SC1)
•
eth0: 10.0.253.1
•
eth1: 10.0.254.1
Site Controller 2 (SC2)
•
eth0: 10.0.254.2
•
eth1: 10.0.253.2
Procedure 8-28
How to Configure Ethernet Ports
1
Reset the Site Controller and press the Esc key when prompted to interrupt the startup sequence.
2
From the prompt, run the command
spr inet/if/eth0
.
3
From the prompt, run the command
spr inet/if/eth1
.
4
Take note of the IP addresses and the MAC addresses.
If the IP addresses are set correctly (as stated in lists prior to this procedure),
continue to
Step 7
below.
If the IP addresses are set incorrectly, they must be changed as follows in the next
step.
5
From the prompt, run the command
spw inet/if/eth0 “dhcp:no
addr:10.0.(252+X).X mask:255.255.255.0 dev_name:tsec dev_unit:0
ethaddr:
yy:yy:yy:yy:yy:yy mtu:1500”
•
There is
one
space between the
ethaddr:
and the
yy:yy:yy:yy:yy:yy
in the command above.
•
X
= 1 for SC1, and 2 for SC2
•
yy:yy:yy:yy:yy:yy
= the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
8-48
6802800U74-N September 2009
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...