MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Hybrid Combiner in MTS 4
Procedure 7-12
How to Update the Mapping List with the New Unit TrackID (Continued)
4
Delete old CAN Bus unit from the CAN Bus unit mapping list. Use
can remove_mapping
<Device>
, where <Device> is the old unit name. See example below:
SC> can remove_mapping dpm 2
5
Add new CAN Bus unit to the CAN Bus unit mapping list.
The new unit Track ID is present on the replaced unit label and indicated as
Track
ID not mapped
in the list shown in
.
Use
can add_mapping <Device> <TrackID>
, where <TrackID> is a TrackID of
the new unit and <Device> is the new unit name: dpm X, where X denotes a digit between 0
and 3). See example below:
SC> can add_mapping dpm 2 JTH0500102
6
View the updated mapping list using the
can check_mapping
command and check that
there are no units labelled as
Track ID not mapped
or
Units are not present
.
Hybrid Combiner in MTS 4
For details about the Hybrid Combiner (HC), see the section
Post Filter
The Post Filter supports non-duplexed con
fi
gurations. The Post Filter incorporates a DPM. A Post Filter
is only available for the MTS 4 because the MTS 2 does not support non-duplexed con
fi
gurations.
The bandwidth is 5 MHz on 400 MHz and 19 MHz on 800 MHz.
6802800U74-N September 2009
7-25
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...