13 - 20
13 AUXILIARY FUNCTION
13.5.3 Related servo amplifier parameters
The relevant servo amplifier parameters are shown below.
POINT
• For any parameter whose symbol is preceded by *, set the parameter value
and switch power off once, then switch it on again to make that parameter
setting valid.
(1) I/O Setting parameter
No.
Symbol
Name and function
Initial value
Unit
Setting range
PD11 *DIF
Input filter setting
Select the input filter.
Input signal filter
0 : None
1 : 0.88ms
2 : 1.77ms
3 : 2.66ms
4 : 3.55ms
4
-
0 to 4
(2) Option card parameter
No.
Symbol
Name and function
Initial value
Unit
Setting range
PO06 D1AD1
Analog input (ANI1) offset of the extension IO unit
Set the offset voltage of the analog input in hexadecimal.
0000h
mV
0000h
to
0FFFFh
(Note-1)
PO07 D1AD2
Analog input (ANI2) offset of the extension IO unit
Set the offset voltage of the analog input in hexadecimal.
0000h
mV
0000h
to
0FFFFh
(Note-1)
PO08 D1DA1
Analog output (ANO1) offset of the extension IO unit
Set the offset voltage of the analog output in hexadecimal.
0000h
mV
0000h
to
0FFFFh
(Note-1)
PO09 D1DA2
Analog output (ANO2) offset of the extension IO unit
Set the offset voltage of the analog output in hexadecimal.
0000h
mV
0000h
to
0FFFFh
(Note-1)
Note-1 : The setting range is -9999mV to 9999mV. If set to outside the range, servo amplifier rounds it to
within the range.
Summary of Contents for MR-MQ100
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 73: ...3 12 3 DESIGN MEMO ...
Page 97: ...5 8 5 TRIAL OPERATION AND ADJUSTMENT MEMO ...
Page 159: ...7 36 7 POSITIONING DEDICATED SIGNALS MEMO ...
Page 167: ...8 8 8 PARAMETERS FOR POSITIONING CONTROL MEMO ...
Page 189: ...9 22 9 SERVO PROGRAMS FOR POSITIONING CONTROL MEMO ...
Page 205: ...10 16 10 MOTION SFC PROGRAMS MEMO ...
Page 245: ...14 4 14 ERROR CODE MEMO ...
Page 253: ...15 8 15 EMC DIRECTIVES MEMO ...
Page 267: ...App 14 APPENDICES MEMO ...
Page 270: ......
Page 271: ......