8 - 4
8 PARAMETERS FOR POSITIONING CONTROL
8.3 JOG Operation Data
(1) The settings for JOG operation is executed.
(2) Individual start or simultaneous start can be used in JOG operation.
(3) JOG operation can be executed using the Motion SFC program or test mode of
MT Developer2.
(Refer to the help of MT Developer2 for JOG operation method in the test mode of
MT Developer2.)
(4) Refer to "Q173DCPU/Q172DCPU Motion controller (SV13/SV22) Programming
Manual (REAL MODE)" for details.
Table 8.3 JOG operation data list
Setting range
mm inch degree PLS
No. Item
Setting
range
Units
Setting
range
Units
Setting
range
Units Setting range
Units
Initial
value
Units
Remarks
1
JOG
speed limit
value
0.01 to
6000000.00
mm
/min
0.001 to
600000.000
inch
/min
0.001 to
2147483.647
(Note-1)
degree/
min
1 to
2147483647
PLS
/s
20000 PLS/s
• Sets the maximum speed at the JOG
operation.
• If JOG speed setting exceeds the JOG
speed limit value, it is controlled with JOG
speed limit value.
2
Parameter
block
setting
1 to 64
1
• Sets the parameter block No. to be used at
the JOG operation.
(Note-1): When the "speed control 10 multiplier speed setting for degree axis" is set to "valid", the setting range is 0.01 to 21474836.47[degree/min].
Summary of Contents for MR-MQ100
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 73: ...3 12 3 DESIGN MEMO ...
Page 97: ...5 8 5 TRIAL OPERATION AND ADJUSTMENT MEMO ...
Page 159: ...7 36 7 POSITIONING DEDICATED SIGNALS MEMO ...
Page 167: ...8 8 8 PARAMETERS FOR POSITIONING CONTROL MEMO ...
Page 189: ...9 22 9 SERVO PROGRAMS FOR POSITIONING CONTROL MEMO ...
Page 205: ...10 16 10 MOTION SFC PROGRAMS MEMO ...
Page 245: ...14 4 14 ERROR CODE MEMO ...
Page 253: ...15 8 15 EMC DIRECTIVES MEMO ...
Page 267: ...App 14 APPENDICES MEMO ...
Page 270: ......
Page 271: ......