2 - 2
2 SYSTEM CONFIGURATION
(2) Peripheral device configuration for the MR-MQ100 system
Peripheral connection options are shown below.
Computer
Ethernet cable
Motion controller
(MR-MQ100)
Part
name
Connection
type
Cable
type
Ethernet
standard
Model name
10BASE-T
Connection
with HUB
Straight
cable
100BASE-TX
10BASE-T
Ethernet
cable
Direct
connection
Crossover
cable
100BASE-TX
Compliant with Ethernet standards, category 5 or higher.
• Shielded twisted pair cable (STP cable)
(a) Selection criterion of cable
• Category : 5 or higher
• Diameter of lead : AWG26 or higher
• Shield : Copper braid shield and drain wire
Copper braid shield and aluminium layered type shield