2 - 26
2 SYSTEM CONFIGURATION
2.5.4 SSCNET cables and connection method
This section describes how to connect between the Motion controller and servo
amplifier.
SSCNET cabling is used between the Motion controller and servo amplifier.
(1) Connection between the MR-MQ100 and servo amplifier
SSCNETⅢ cable length
・ MR-J3BUS□M use
①≦3m(9.84ft)
・ MR-J3BUS□M-A use
①≦20m(65.62ft)
・ MR-J3BUS□M-B use
①≦50m(164.04ft)
Servo amplifier
CN1A
CN1B
①
Cap
PULL
CN1
(Note): Communication will not be possible if CN1A and CN1B are mistaken for one-another.
List of SSCNET cable model name
Model name
(Note)
Cable
length
Description
MR-J3BUS M
0.15m(0.49ft.), 0.3m(0.98ft.), 0.5m(1.64ft.),
1m(3.28ft.), 3m(9.84ft.)
Standard cord for
inside panel
MR-J3BUS M-A 5m(16.4ft.),
10m(32.81ft.),
20m(65.62ft.)
Standard cable for
outside panel
MR-J3BUS M-B
30m(98.43ft.), 40m(131.23ft.), 50m(164.04ft.)
Long distance cable
• MR-MQ100
MR-J3- B
(Note) : =cable length