14 - 3
14 ERROR CODE
14.3 Servo program setting error
MR-MQ100 has the same "Servo program setting errors" as Q173DCPU/Q172DCPU
except for the below error. Refer to "Q173DCPU/Q172DCPU Motion controller
SV13/SV22 Programming Manual (REAL MODE)" for all other errors.
Table 14.3 Servo programming setting error
Error
code
Error name
Error contents
Error processing
Corrective action
51
Rapid stop
deceleration time
setting error
The rapid stop deceleration
time is bigger than the setting
value of deceleration time.
Control with the setting value
of deceleration time.
Set the rapid stop deceleration time within
the range of 1 to deceleration time.