2 - 25
2 SYSTEM CONFIGURATION
• Termination of the cables
When the 24VDC power supply cable is produced with the customer, a
crimping tool is necessary.
Please refer to the manual of the manufacturing maker of the crimp tool
for details.
2mm +/-0.3mm
Sheath
Core
1827587-2 terminal
0.1 to 0.65mm
CAUTION
24V(+) pin is upper side and 24G pin is lower side of 24VDC connector of MR-MQ100. If the
polarity is wrong, the unit may be damaged.
Recommend the use of twisted pair cabling for 24VDC input.
Power off the unit before wiring 24VDC input.
Use proper size wire for 24VDC.
Do not connect to pins "1A" or "2A" of the 24VDC power input connector.