13 - 10
13. COMMUNICATION FUNCTION
13.4 Command and data No. list
POINT
If the command and data No. are the same, the description may be different
from that of the servo amplifier.
13.4.1 Read commands
(1) Status display (Command [0][1])
Command
Data No.
Description
Display Item
Frame Length
[0][0] Cumulative
feedback
pulse
[0][1]
Servo motor speed
[0][2] Droop
pulse
[0][3] Cumulative
command
pulse
[0][4] Command
pulse
frequency
[0][5] Analog
speed
command
voltage
Analog speed limit voltage
[0][6] Analog
torque
command
voltage
Analog torque limit voltage
[0][7] Regenerative
load
ratio
[0][8] Effective
load
ratio
[0][9] Peak
load
ratio
[0][A] Instantaneous
torque
[0][B]
Within one-revolution position
[0][C] ABS
counter
[0][D]
Load inertia moment ratio
[0][E]
Status display name and unit
Bus voltage
16
[8][0] Cumulative
feedback
pulse
[8][1]
Servo motor speed
[8][2] Droop
pulse
[8][3] Cumulative
command
pulse
[8][4] Command
pulse
frequency
[8][5] Analog
speed
command
voltage
Analog speed limit voltage
[8][6] Analog
torque
command
voltage
Analog torque limit voltage
[8][7] Regenerative
load
ratio
[8][8] Effective
load
ratio
[8][9] Peak
load
ratio
[8][A] Instantaneous
torque
[8][B]
Within one-revolution position
[8][C] ABS
counter
[8][D]
Load inertia moment ratio
[0][1]
[8][E]
Status display data value and
processing information
Bus voltage
12