12 - 76
12. OPTIONS AND AUXILIARY EQUIPMENT
12.19 EMC filter (recommended)
For compliance with the EMC directive of the EN Standard, it is recommended to use the following filter: Some
EMC filters are large in leakage current.
(1) Combination with the servo amplifier
Recommended filter (Soshin Electric)
Servo amplifier
Model
Leakage current [mA]
Mass [kg]([lb])
MR-J3-10A to MR-J3-100A
MR-J3-10A1 to MR-J3-40A1
(Note) HF3010A-UN
3 (6.61)
MR-J3-250A MR-J3-350A (Note)
HF3030A-UN
5
5.5 (12.13)
MR-J3-500A MR-J3-700A
(Note) HF3040A-UN
1.5
6.0 (13.23)
MR-J3-11KA to MR-J3-22KA
(Note) HF3100A-UN
6.5
15 (33.07)
MR-J3-60A4 to MR-J3-100A4
TF3005C-TX
MR-J3-200A4 MR-J3-700A4 TF3020C-TX
6(13.23)
MR-J3-11KA4 TF3030C-TX
7.5(16.54)
MR-J3-15KA4 TF3040C-TX
MR-J3-22KA4 TF3060C-TX
5.5
12.5(27.56)
Note. A surge protector is separately required to use any of these EMC filters.
(2) Connection example
L
1
L
2
L
3
11
L
21
Servo amplifier
1
2
3
4
5
6
E
MC
(Note 2)
Surge protector 1
(RAV-781BYZ-2)
(OKAYA Electric Industries Co., Ltd.)
(Note 2)
Surge protector 2
(RAV-781BXZ-4)
(OKAYA Electric Industries Co., Ltd.)
NFB
(Note 1)
Power supply
1
2
3
1
2
3
EMC filter
Note 1. For 1-phase 200V to 230VAC power supply, connect the power supply to L
1
,L
2
and leave L
3
open.
There is no L
3
for 1-phase 100 to 120VAC power supply. Refer to section 1.2 for the power supply specification.
2. The example is when a surge protector is connected.
Summary of Contents for MELSERVO MR-J3 A Series
Page 15: ...A 14 MEMO ...
Page 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Page 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Page 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...