12 - 56
12. OPTIONS AND AUXILIARY EQUIPMENT
(c) To diagnose the trouble using diagnosis cable (MR-J3ACHECK)
POINT
The amplifier diagnosis function can be used with the following software
versions of the servo amplifier.
Servo amplifier: A1 or later
Do not turn the power on with all connectors connected.
Do not connect or disconnect connectors after the power is turned on.
Otherwise failure will be caused.
This cable is a diagnosis cable of the servo amplifier. The amplifier diagnosis function of MR Configurator can
be used when this cable is used.
Cable Model
Application
MR-J3ACHECK
Amplifier diagnosis cable for MR Configurator.
Connection between the servo amplifier and servo motor is shown in the figure below.
CN5
CN6
CN1
CN2
MR-J3ACHECK
USB cable
MR-J3USBCBL3M
(Option)
Servo amplifier
1)
2)
3)
To USB
connector
Personal computer
Cable Model
1) For CN6 Connector
2) For CN1 Connector
3) For CN2 Connector
MR-J3ACHECK Housing:
51004-0300
Contact: 50011-8000
(Molex)
Plug: 10150-3000VE
Shell kit: 10350-52F0-008
(3M)
Receptacle: 36210-0100JE
Shell kit: 36310-3200-008
(3M or equivalent)