6 - 6
6. DISPLAY AND OPERATION SECTIONS
Name Symbol
Unit
Description
Display
range
Within one-revolution
position high
Cy2 100
pulse
The within one-revolution position is displayed in 100 pulse increments of
the encoder.
The value returns to 0 when it exceeds the maximum number of pulses.
The value is incremented in the CCW direction of rotation.
0
to
2621
ABS counter
LS
rev
Travel value from the home position in the absolute position detection
systems is displayed in terms of the absolute position detectors counter
value.
32768
to
32767
Load inertia moment
ratio
dC 0.1
Times
The estimated ratio of the load inertia moment to the servo motor shaft
inertia moment is displayed.
0.0
to
300.0
Bus voltage
Pn
V
The voltage (across P-N) of the main circuit converter is displayed.
0
to
900
6.3.4 Changing the status display screen
The status display item of the servo amplifier display shown at power-on can be changed by changing the
parameter No. PC36 settings.
The item displayed in the initial status changes with the control mode as follows:
Control mode
Status display at power-on
Position Cumulative
feedback
pulses
Position/speed
Cumulative feedback pulses/servo motor speed
Speed
Servo motor speed
Speed/torque
Servo motor speed/analog torque command voltage
Torque Analog
torque
command
voltage
Torque/position
Analog torque command voltage/cumulative feedback pulses