14 - 23
14. ABSOLUTE POSITION DETECTION SYSTEM
(2) Sequence program example
(a) Conditions
1) Operation pattern
ABS data transfer is made as soon as the servo-on pushbutton is turned on. After that, positioning
operation is performed as shown below:
300000
0
address
3)
1)
2)
Home position
300000
After the completion of ABS data transmission, JOG operation is possible using the JOG or JOG
pushbutton switch.
After the completion of ABS data transmission, dog type home position return is possible using the
home position return pushbutton switch.
2) Buffer memory assignment
For BFM#26 and later, refer to the FX
2(N)
-1PG User's Manual.
BMF No.
Upper 16
bits
Lower 16
bits
Name and symbol
Set value
Remark
-
#0 Pulse
rate
A
2000
#2 #1
Feed
rate
B 1000
- #3
Parameter
H0000
Command
unit:
Pulses
#5 #4
Max.
speed
Vmax
100000PPS
- #6
Bias
speed
Vbia 0PPS
#8 #7
JOG
operation
Vjog
10000PPS
#10
#9
Home position return speed (high speed)
V
RT
50000PPS
-
#11
Home position return speed (creep)
V
CL
1000PPS
-
#12
Home position return zero-point signal count
N
2 pulses
Initial value: 10
#14
#13
Home position address
HP
0
-
#15
Acceleration/deceleration time
Ta
200ms
Initial value: 100
- #16
Not
usable
#18
#17
Target address (I)
P(I)
0
#20
#19
Operation speed (I)
V(I)
100000
Initial value: 10
#22
#21
Target address (II)
P(II)
0
#24 #23
Operation
speed
(II)
V(II)
10
- #25
Operation
command
H0000
3) Instructions
When the servo-on pushbutton switch and the GND of the power supply are shorted, the ABS data is
transmitted when the servo amplifier power is turned ON, or at the leading edge of the RUN signal
after a PC reset operation (PC-RESET). The ABS data is also transmitted when an alarm is reset, or
when the emergency stop state is reset.
If check sum discrepancy is detected in the transmitted data, the ABS data transmission is retried up
to three times. If the check sum discrepancy is still detected after retrying, the ABS check sum error is
generated (Y12 ON).
The following time periods are measured and if the ON/OFF state does not change within the
specified time, the ABS communication error is generated (Y11 ON).
ON period of ABS transfer mode (Y1)
ON period of ABS request (Y2)
OFF period of ready to send the ABS data (X2).