5 - 13
5. PARAMETERS
5.1.12 Selection of command pulse input form
Parameter Control
Mode
No. Symbol
Name
Initial
Value
Unit
Setting
Range Position Speed Torque
PA13 *PLSS Command pulse input form
0000h
Refer to
the text.
POINT
This parameter is made valid when power is switched off, then on after setting.
Select the input form of the pulse train input signal. Command pulses may be input in any of three different
forms, for which positive or negative logic can be chosen.
Arrow
or
in the table indicates the timing of importing a pulse train.
A- and B-phase pulse trains are imported after they have been multiplied by 4.
Selection of command pulse input form
Setting
Pulse train form
Forward rotation command
Reverse rotation command
0010h
Forward rotation pulse train
Reverse rotation pulse train
NP
PP
0011h Pulse
train
sign
PP
L
H
NP
0012h
Negat
iv
e l
ogi
c
A-phase pulse train
B-phase pulse train
PP
NP
0000h
Forward rotation pulse train
Reverse rotation pulse train
NP
PP
0001h Pulse
train
sign
L
H
PP
NP
0002h
Po
si
tive
lo
gi
c
A-phase pulse train
B-phase pulse train
PP
NP
Summary of Contents for MELSERVO MR-J3 A Series
Page 15: ...A 14 MEMO ...
Page 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Page 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Page 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...