14 - 42
14. ABSOLUTE POSITION DETECTION SYSTEM
(d) X-axis program
Do not execute the X-axis program while the ABS ready (M8) is off.
M10
When "M10" (ready to send ABS data) switches on,
the X-axis start program is executed by the X-axis
start command.
X-axis start program
Positioning
mode
X-axis start
command
Ready to
send ABS
data
(Note)
(e) Dog type home position return
Refer to the home position return program in the A1SD75 User
'
s Manual.
Note that this program requires a program which outputs the clear (CR) (Y35) after completion of home
position return.
Add the following program:
K1
D12
K817
H0000
FROM
M22
D12
K0016
WAND
Y35
D12 K16
M22
Reading 1-axis home position return
completion signal
Masking home position return completion
Home position return processing instruction
Switching clear (CR) on
Home position return
start command
Processing
instruction
Home position return
completion judgment