13 - 12
13. COMMUNICATION FUNCTION
(4) Alarm history (Command [3][3])
Command
Data No.
Description
Alarm Occurrence Sequence
Frame Length
[1] [0]
most recent alarm
[1] [1]
first alarm in past
[1] [2]
second alarm in past
[1] [3]
third alarm in past
[1] [4]
fourth alarm in past
[1] [5]
Alarm number in alarm history
fifth alarm in past
4
[2] [0]
most recent alarm
[2] [1]
first alarm in past
[2] [2]
second alarm in past
[2] [3]
third alarm in past
[2] [4]
fourth alarm in past
[3] [3]
[2] [5]
Alarm occurrence time in alarm history
fifth alarm in past
8
(5) Current alarm (Command [0][2])
Command Data
No.
Description
Frame
Length
[0] [2]
[0] [0]
Current alarm number
4