14 - 60
14. ABSOLUTE POSITION DETECTION SYSTEM
(c) At the time of alarm reset
If an alarm has occurred, detect the trouble (ALM) and turn off the servo-on (SON). After removing the
alarm occurrence factor and deactivating the alarm, get the absolute position data again from the servo
amplifier in accordance with the procedure in (a) of this section.
ON
95ms
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ABS data
5ms
Base circuit
Absolute position data
command transmission
Absolute position
data receive
Current position
Pulse train command
During this period, get absolute position data.
Current position change
Servo-on
(SON)
Reset
(RES)
Trouble
(ALM)
Ready
(RD)