3 - 60
3. SIGNALS AND WIRING
(2) HF-SP series HC-RP series HC-UP series HC-LP series servo motor
POINT
Insert a contact in the direction shown in the figure. If inserted in the wrong
direction, the contact is damaged and falls off.
Soldered part
or crimping part
facing up
Soldered part or
crimping part
facing down
Pin No.1
Pin No.1
For CM10-SP10S-
For CM10-SP2S-
(a) Wiring diagrams
Refer to section 12.11 for the cables used for wiring.
Electromagnetic
brake (MBR)
Servo motor
Emergency
stop
(EMG)
(Note)
Servo amplifier
U
V
W
B1
B2
U
V
W
24VDC power
supply for
electromagnetic
brake
50m or less
M
Trouble
(ALM)
When the power supply connector and the electromagnetic brake connector are separately supplied
Servo motor
Servo amplifier
M
U
V
W
B1
B2
U
V
W
Electromagnetic
brake (MBR)
Emergency
stop
(EMG)
(Note)
24VDC power
supply for
electromagnetic
brake
Trouble
(ALM)
When the power supply connector and the electromagnetic brake connector are shared
Note. There is no polarity in electromagnetic brake terminals B1 and B2.