5 - 31
5. PARAMETERS
No. Symbol
Name
and
Function
Initial
Value
Unit
Setting
Range
Control Mode
PC14 MOD1 Analog monitor 1 output
Used to selection the signal provided to the analog monitor 1
(MO1) output. (Refer to section 5.3.3)
C
B
0 0 0
0
1
2
3
4
5
6
7
8
9
A
D
Analog monitor 1 (MO1) output selection
Setting
Item
Note1. Encoder pulse unit.
Servo motor speed ( 8V/max. speed)
Torque ( 8V/max. torque) (Note 2)
Servo motor speed (+8V/max. speed)
Torque (+8V/max. torque) (Note 2)
Current command ( 8V/max. current command)
Command pulse frequency ( 10V/1Mpps)
Droop pulses ( 10V/100 pulses) (Note 1)
Droop pulses ( 10V/1000 pulses) (Note 1)
Droop pulses ( 10V/10000 pulses) (Note 1)
Droop pulses ( 10V/100000 pulses) (Note 1)
Feedback position ( 10V/1 Mpulses) (Note 1)
Feedback position ( 10V/10 Mpulses) (Note 1)
Feedback position ( 10V/100 Mpulses) (Note 1)
Bus voltage ( 8V/400V) (Note 3)
2. 8V is outputted at the maximum torque.
However, when parameter No. PA11 PA12 are
set to limit torque, 8V is outputted at the torque
highly limited.
3. For 400V class servo amplifier, the bus voltage
b8V/800V.
0000h
Refer
to
the
Name
and
Function
field.
PC15 MOD2 Analog monitor 2 output
Used to selection the signal provided to the analog monitor 2
(MO2) output. (Refer to section 5.3.3)
0 0 0
Select the analog monitor 2 (MO2) output
The settings are the same as those of
parameter No. PC14.
0001h
Refer
to
the
Name
and
Function
field.
PC16 MBR Electromagnetic brake sequence output
Used to set the delay time (Tb) between electronic brake interlock
(MBR) and the base drive circuit is shut-off.
100 ms
0
to
1000
PC17 ZSP Zero
speed
Used to set the output range of the zero speed (ZSP).
Zero speed signal detection has hysteresis width of 20r/min (refer
to section 3.5 (1) (b))
50 r/min
0
to
10000
PC18 *BPS Alarm history clear
Used to clear the alarm history.
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm
history is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
0 0 0
0000h
Refer
to
the
Name
and
Function
field.
Summary of Contents for MELSERVO MR-J3 A Series
Page 15: ...A 14 MEMO ...
Page 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Page 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Page 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...