13 - 25
13. COMMUNICATION FUNCTION
13.5.6 Disable/enable of I/O devices (DIO)
Inputs can be disabled independently of the I/O devices ON/OFF. When inputs are disabled, the input signals
(devices) are recognized as follows. Among the input devices, EMG, LSP and LSN cannot be disabled.
Signal Status
Input devices (DI)
OFF
External analog input signals
0V
Pulse train inputs
None
(1) Disabling/enabling the input devices (DI), external analog input signals and pulse train inputs with the
exception of EMG, LSP and LSN.
Transmit the following communication commands:
(a) Disable
Command Data
No.
Data
[9][0] [0][0]
1EA5
(b) Enable
Command Data
No.
Data
[9][0] [1][0]
1EA5
(2) Disabling/enabling the output devices (DO)
Transmit the following communication commands:
(a) Disable
Command Data
No.
Data
[9][0] [0][3]
1EA5
(b) Enable
Command Data
No.
Data
[9][0] [1][3]
1EA5
13.5.7 Input devices ON/OFF (test operation)
Each input devices can be turned on/off for test operation. when the device to be switched off exists in the
external input signal, also switch off that input signal.
Send command [9] [2], data No. [0] [0] and data.
Command
Data No.
Set data
[9][2] [0][0]
See
below
b31
b0
0: OFF
1: ON
b1
Command of each bit is transmitted to the slave
station as hexadecimal data.
bit Abbreviation
bit Abbreviation
bit Abbreviation
bit Abbreviation
0
SON
8
SP1
16
24
1 LSP
9 SP2
17
25
2
LSN
10
SP3
18
26
3 TL
11
ST1
19
27
CDP
4 TL1
12 ST2
20
STAB2
28
5 PC
13
CM1
21
29
6
RES
14
CM2
22
30
7 CR
15
LOP
23
31
Summary of Contents for MELSERVO MR-J3 A Series