12 - 65
12. OPTIONS AND AUXILIARY EQUIPMENT
12.13 Power factor improving DC reactor
POINT
For the 100VAC power supply type (MR-J3- A1), the power factor improving
DC reactor cannot be used.
The power factor improving DC reactor increases the form factor of the servo amplifier's input current to
improve the power factor. It can decrease the power supply capacity. As compared to the power factor
improving AC reactor (FR-BAL), it can decrease the loss. The input power factor is improved to about 95%.
It is also effective to reduce the input side harmonics.
When connecting the power factor improving DC reactor to the servo amplifier, always disconnect the wiring
across P
1
-P
2
(For 11kW or more, disconnect the wiring across P-P
1
). If it remains connected, the effect of the
power factor improving DC reactor is not produced.
When used, the power factor improving DC reactor generates heat. To release heat, therefore, leave a 10cm
or more clearance at each of the top and bottom, and a 5cm or more clearance on each side.
Rating plate
L
H
B or less
E
A or less
Terminal box - screw size G
Mounting leg
D
F
C o
r less
Servo amplifier
P
1
P
2
(Note 2)
FR-BEL-(H)
2-F L notch
5m or less
Servo amplifier
P
1
P
2
(Note 2)
FR-BEL-(H)
(Note 3)
B or less
A or less
Mounting leg
Rating plate
2-F L notch
Screw size G
(Note 1)Terminal cover
E
D
H
F
L
C or
le
ss
5m or less
Fig. 12.1
Fig. 12.2
Note 1. Since the terminal cover is supplied, attach it after connecting a wire.
2. When using DC reactor, disconnect the wiring across P
1
-P
2
.
3. When over 11kW, "P
2
" becomes "P", respectively.
Dimensions
[mm]
Servo Amplifier
Power Factor
Improving DC
Reactor
Outline
drawing
A B C D E F L G H
Mounting
Screw Size
Mass
[kg(lb)]
Used Power
Supply
[mm
2
]
MR-J3-10A
20A
FR-BEL-0.4K 110
50
94
1.6
95
6
12
M3.5
25 M5 0.5(1.10)
MR-J3-40A FR-BEL-0.75K 120
53
102
1.6
105
6
12
M4
25 M5 0.7(1.54)
MR-J3-60A
70A
FR-BEL-1.5K 130
65
110
1.6
115
6
12
M4
30 M5 1.1(2.43)
2(AWG14)
MR-J3-100A FR-BEL-2.2K
Fug.
12.1
130
65
110
1.6
115
6 12
M4
30 M5 1.2(2.65)
MR-J3-200A FR-BEL-3.7K 150
75
102
2.0
135
6
12
M4
40 M5 1.7(3.75)
MR-J3-350A FR-BEL-7.5K 150
75
126
2.0
135
6
12
M5
40 M5 2.3(5.07)
3.5(AWG12)
MR-J3-500A FR-BEL-11K 170
93
132
2.3
155
6
14
M5
50 M5 3.1(6.83)
5.5(AWG10)
MR-J3-700A
8(AWG8)
MR-J3-11KA
FR-BEL-15K 170
93
170
2.3
155
6
14
M8
56
M5
3.8(8.38)
22(AWG4)
MR-J3-15KA FR-BEL-22K
Fig. 12.2
185 119 182 2.6 165 7 15 M8 70
M6
5.4(11.91) 30(AWG2)
MR-J3-22KA FR-BEL-30K 185
119
201
2.6
165
7
15
M8
70 M6 6.7(14.77)
60(AWG2/0)
MR-J3-60A4
FR-BEL-H1.5K 130
63
89
1.6
115
6
12
M3.5
32 M5 0.9(1.98)
MR-J3-100A4
FR-BEL-H2.2K 130
63
101
1.6
115
6
12
M3.5
32 M5 1.1(2.43)
MR-J3-200A4 FR-BEL-H3.7K
Fig.
12.1
150 75 102 2 135 6 12 M4 40 M5 1.7(3.75)
2(AWG14)
MR-J3-350A4 FR-BEL-H7.5K 150 75 124 2 135 6 12 M4 40 M5 2.3(5.07)
MR-J3-500A4
FR-BEL-H11K 170
93
132
2.3
155
6
14
M5
50 M5 3.1(6.83)
5.5(AWG10)
MR-J3-700A4
MR-J3-11KA4
FR-BEL-H15K 170
93
160
2.3
155
6
14
M6
56
M5
3.7(8.16)
8(AWG8)
MR-J3-15KA4 FR-BEL-H22K
Fig. 12.2
185 119 171 2.6 165 7 15 M6 70
M6
5.0(11.02)
MR-J3-22KA4
FR-BEL-H30K 185
119
189
2.6
165
7
15
M6
70 M6 6.7(14.77)
22(AWG4)
Summary of Contents for MELSERVO MR-J3 A Series
Page 15: ...A 14 MEMO ...
Page 225: ...7 12 7 GENERAL GAIN ADJUSTMENT MEMO ...
Page 241: ...8 16 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 251: ...9 10 9 TROUBLESHOOTING MEMO ...
Page 263: ...10 12 10 OUTLINE DRAWINGS MEMO ...