12 - 37
12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
NFB
MC
Servo amplifier
L
11
L
21
L
1
L
2
L
3
SK
ON
MC
B C
N
P
C
RDY
SE
Alarm
output
RDY
output
A
B
C
5m or less
Operation ready
MC
OFF
EMG
RA2
FR-RC
Ready
Power factor improving reactor
FR-BAL
R/L
1
S/L
2
T/L
3
B
C
R
RX
R
SX
S
TX
T
Phase detection
terminals
(Note 1)
Power regeneration
converter FR-RC(-H)
N/
P/
SON
EMG
RA
DOCOM
DICOM
ALM
Trouble
Servo-on
(Note 3)
(Note 3)
DOCOM
Emergency
stop
24VDC
P
2
P
1
(Note 4)
(Note 2)
CN1
CN1
(Note 5)
(Note 6)
Power supply
Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the
FR-RC(-H) will not operate.
2. When using servo amplifier of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected to P terminal
and C terminal.
3. For sink input-output interface. Refer to section 3.8.3 for source input-output interface.
4. Always connect P
1
-P
2
(For 11k to 22kW, connect P-P
1
). (Factory-wired.) When using the power factor improving DC reactor,
refer to section 12.13.
5. For 400VAC class, the stepdown transformer is required.
6. For the specification of power supply, refer to section 1.3.