97
03/05
SPIDER MAX 500
B
F. 80
Make sure that the sensor circuit is insulated from the ground.
PIN 4 - PIN 23 =
Ω
infinitive (>1M
Ω
)
PIN 22 - PIN 23 =
Ω
infinitive (>1M
Ω
)
Restore or replace the connections. Check the position of the
air temperature and gas valve lines.
Connect the testing wiring to the central unit
(connector - B).
Move the key switch to the “ON” position an the
emergency switch to “RUN” and lift the side stand.
Measure the voltage across PIN 4 and PIN 22;
PIN 4 - PIN 22 = V (see table)
Measured value = 5 ± 0,2 V.
Repeat the check concerning the
connection and sensor continuity.
Measured value = 0 V.
Repeat the check of the circuit and
sensor insulation from the ground.
VOLTAGE TEMPERATURE
4,50 V - 10° C
3,73 V 0
3,25 V + 10° C
2,76 V + 20° C
2,26 V + 30° C
0,70 V + 80° C
F. 81
F. 79
SEE TABLE