SLC
®
-2000 Access System
RT Frame Assembly Manual
Issue 5
May 1997
3-1
Lucent Technologies
363-208-010
3
Cabling, Wiring, and Assembly
Cable Assembly Descriptions
Cable Description
Factory Assemblies
Two types of cabling operations are required for connecting factory assemblies.
The first is the connecting of Shelf Dangler Cables to other shelf dangler cables.
The second is the placement and connecting of intershelf cable assemblies that
are common to each shelf (i.e. power, ringing and test functions). These
Standard Bay Cable Assemblies are preconnectorized at the factory, and
installation consists of putting the right connectors together when mounting new
shelves or if cables had been disconnected for packing purposes. Factory
assemblies utilize connectors of the Insulation Displacement Connection (IDC)
type with low-profile hood assemblies.
Customer Interface Cable Assemblies
These assemblies consist of external cables that interconnect the
SLC
-2000 RT
Bay to various other systems and ancillary equipment such as the following:
a. VF customer lines for cross connections at a FDI block.
b. DS1 line connections for cross connections at the DSX.
c. Optical fiber jumpers for cross connections at the LGX for lightwave sys-
tems.
d. Alarm connections for RT inputs.
e. DC Test Pair connections for subscriber testing facilities.
f. Discrete alarm connections for environment status and controls.
g. Power connections from the -48 volt battery plant.
h. Ringing connections from the customer’s positive and/or negative ringing
supplies.
Summary of Contents for SLC-2000 Access System Central Office Terminal
Page 1: ...SLC 2000 Access System Customer Assembly Manual for RT Frames 363 208 010 Issue 5 May 1997...
Page 4: ...This page is intentionally blank...
Page 10: ...viii Issue 5 May 1997 Contents...
Page 16: ...xiv Issue 5 May 1997 Tables...
Page 24: ...1 ii Issue 5 May 1997 Contents General Information...
Page 34: ...2 iv Issue 5 May 1997 Tables Installation Procedures 2 1 Dimensions for Figure 2 2 6...
Page 66: ...3 viii Issue 5 May 1997 Contents Cabling Wiring and Assembly...