background image

3M

 Indoor Protected Building Entrance 

Terminal 4588V-QCS Series 

with 3M

 Quick Connect System 2811 

Dry Flame Retardant Block

Instructions

Underwriters Laboratories (UL 348X) Listed

April 2010
78-0013-1813-4-A

3

Summary of Contents for 4588QCS-HCCA/100SD

Page 1: ...Indoor Protected Building Entrance Terminal 4588V QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories UL 348X Listed April 2010 78 0013 1813 4 A 3 ...

Page 2: ...10 Splicing System SD modules b Splice chamber for the feeder cable with cable strain relief Note diagram c Insulated 6 ground strap for the feeder cable d External bottom mounted three point ground bar and top mounted single point ground bar Note diagram e Numbered standard 5 pin protector receptacle field Note diagram f Binding post log and instruction label g The 3M Single Pair Test Probe and D...

Page 3: ...rt stub insulated ground wire and accessories out of the splicing chamber 2 4 Mount the terminal in designated position with the three mounting screws provided 2 5 Remove the jumper wire retaining ring from poly bag and install in faceplate 3 0 Feeder Cable Preparation and Strain Relief 3 1 Feeder cable diameters for the 3M Indoor Building Entrance Terminal IBET 4588V QCS Series PET Pair Count Fee...

Page 4: ...te Failure to properly bond and ground the terminal per N E C or local equivalent codes may render protection arrestors useless 4 2 Module splicing Splice per your company practice 4 3 Splice the feeder cable groups to the corresponding connectorized stubs according to your company s practice 4 4 3M Scotchlok Connector or individual connector splicing 4 5 Splice the feeder cable groups to the corr...

Page 5: ... least 5 cm 2 in of slack 6 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3 1 and 3 2 6 5 Terminate additional jumper wires by repeating the above procedure 6 6 To remove jumper wires open the cap and pull the wires straight out from block 6 7 Route the wire below the connected cap 7 0 Installing the Electrical Protectors Note Use ONLY UL Recog...

Page 6: ... cover closed the exposed hasp allows for locking when security is required 9 0 3M Single Pair Test Probe 2827 9 1 Testing using 3M Single Pair Test Probe 2827 9 2 Plug the test probe into the cap of the pair being tested with the black lead to the left and the red lead to the right 10 0 3M Priority Caps 10 1 Priority Caps are used to designate special purpose circuits and prevent entry of the 3M ...

Page 7: ...tack the IBET terminal vertically up to three of the same cable pair count and within the diameter limits in the chart in 3 01 11 2 Mounting the IBET terminal a Mount the IBET terminal bodies using the cable glands to position them b Assemble the feeder cable strain relief according to Section 3 0 and prepare the feeder cable so that 21 of free conductor length will be in the last IBET terminal 1 ...

Page 8: ...8 78 0013 1813 4 A ...

Page 9: ...78 0013 1813 4 A 9 ...

Page 10: ...ranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s...