4
78-0013-1813-4-A
3.6 Remove the sheath, leaving at least 21" of free
conductor length. Identify and secure the cable
groups ends. Bond the cable shield according to
your company’s practice.
3.7 Insert the gland’s groove into the cable port. Slide
the 3M
™
Pull ’N’ Shrink Tube (PST) over the
gland and slowly unwind the core. The PST fits
over either the small diameter of the 25-50 pair
gland or butts up against the 3M
™
Indoor Building
Entrance Terminal (IBET) 4588V-QCS for the 100
pair gland.
822357
25-50
pair
843016
3.8 Complete the PST core removal over the gland.
3.9 The blank plate MUST be used in the empty cable
port for UL Listing.
3.10 Attach the cable to the wall according to your
company’s practice.
4.0 Terminal Grounding
4.1 Fasten a #6 AWG wire to the ground bar which is located on the front of the unit. Connect other end of ground
wire to local ground per company standards.
Note: Failure to properly bond and ground the terminal per N.E.C. or local equivalent codes may render
protection arrestors useless.
4.2 Module splicing. Splice per your company practice.
4.3 Splice the feeder cable groups to the corresponding connectorized stubs according to your company’s practice.
4.4 3M
™
Scotchlok
™
Connector or individual connector splicing
4.5 Splice the feeder cable groups to the corresponding connectorized stubs in the IBET terminal according to your
company’s practice.
4.6 When all splicing is completed, bundle the groups and secure them with tie wraps into the splice chamber on the
left side.
4.7 Close the IBET terminal splice chamber cover and secure with the lockplate bolt. (See 7.02)
5.0 Distribution (House) Wire Termination
5.1 Remove the block from frame. Rotate the block
180°. backward and remount in same frame
position with 1-pair jumper caps facing out.
Push the block firmly into place on the frame.
Cable pairs should now enter the back side of
the block from below. Repeat until all feeder and
distribution blocks have been terminated and
mounted to frame.