3.6  Remove the sheath, leaving at least 21" of free 

conductor length. Identify and secure the cable 
groups ends. Bond the cable shield according to 
your company’s practice.

3.7  Insert the gland’s groove into the cable port. Slide 

the 3M

 Pull ’N’ Shrink Tube (PST) over the 

gland and slowly unwind the core. The PST fits 
over either the small diameter of the 25-50 pair 
gland or butts up against the 3M

 Indoor Building 

Entrance Terminal (IBET) 4588V-QCS for the 100 
pair gland.

822357

25-50

pair

843016

3.8  Complete the PST core removal over the gland.

3.9  The blank plate MUST be used in the empty cable 

port for UL Listing.

3.10  Attach the cable to the wall according to your 

company’s practice.

4.0  Terminal Grounding

4.1  Fasten a #6 AWG wire to the ground bar which is located on the front of the unit.  Connect other end of ground 

wire to local ground per company standards.

Note:   Failure to properly bond and ground the terminal per N.E.C. or local equivalent codes may render 

protection arrestors useless.

4.2  Module splicing. Splice per your company practice.

4.3  Splice the feeder cable groups to the corresponding connectorized stubs according to your company’s practice.

4.4  3M

 

Scotchlok

 Connector or individual connector splicing

4.5  Splice the feeder cable groups to the corresponding connectorized stubs in the IBET terminal according to your 

company’s practice.

4.6  When all splicing is completed, bundle the groups and secure them with tie wraps into the splice chamber on the 

left side.

4.7  Close the IBET terminal splice chamber cover and secure with the lockplate bolt. (See 7.02)

5.0  Distribution (House) Wire Termination

5.1  Remove the block from frame. Rotate the block 

180°. backward and remount in same frame 
position with 1-pair jumper caps facing out. 
Push the block firmly into place on the frame. 
Cable pairs should now enter the back side of 
the block from below. Repeat until all feeder and 
distribution blocks have been terminated and 
mounted to frame.

Summary of Contents for 4588QCS-HCCA/100SD

Page 1: ...Indoor Protected Building Entrance Terminal 4588V QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories UL 348X Listed April 2010 78 0013 1813 4 A 3 ...

Page 2: ...10 Splicing System SD modules b Splice chamber for the feeder cable with cable strain relief Note diagram c Insulated 6 ground strap for the feeder cable d External bottom mounted three point ground bar and top mounted single point ground bar Note diagram e Numbered standard 5 pin protector receptacle field Note diagram f Binding post log and instruction label g The 3M Single Pair Test Probe and D...

Page 3: ...rt stub insulated ground wire and accessories out of the splicing chamber 2 4 Mount the terminal in designated position with the three mounting screws provided 2 5 Remove the jumper wire retaining ring from poly bag and install in faceplate 3 0 Feeder Cable Preparation and Strain Relief 3 1 Feeder cable diameters for the 3M Indoor Building Entrance Terminal IBET 4588V QCS Series PET Pair Count Fee...

Page 4: ...te Failure to properly bond and ground the terminal per N E C or local equivalent codes may render protection arrestors useless 4 2 Module splicing Splice per your company practice 4 3 Splice the feeder cable groups to the corresponding connectorized stubs according to your company s practice 4 4 3M Scotchlok Connector or individual connector splicing 4 5 Splice the feeder cable groups to the corr...

Page 5: ... least 5 cm 2 in of slack 6 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3 1 and 3 2 6 5 Terminate additional jumper wires by repeating the above procedure 6 6 To remove jumper wires open the cap and pull the wires straight out from block 6 7 Route the wire below the connected cap 7 0 Installing the Electrical Protectors Note Use ONLY UL Recog...

Page 6: ... cover closed the exposed hasp allows for locking when security is required 9 0 3M Single Pair Test Probe 2827 9 1 Testing using 3M Single Pair Test Probe 2827 9 2 Plug the test probe into the cap of the pair being tested with the black lead to the left and the red lead to the right 10 0 3M Priority Caps 10 1 Priority Caps are used to designate special purpose circuits and prevent entry of the 3M ...

Page 7: ...tack the IBET terminal vertically up to three of the same cable pair count and within the diameter limits in the chart in 3 01 11 2 Mounting the IBET terminal a Mount the IBET terminal bodies using the cable glands to position them b Assemble the feeder cable strain relief according to Section 3 0 and prepare the feeder cable so that 21 of free conductor length will be in the last IBET terminal 1 ...

Page 8: ...8 78 0013 1813 4 A ...

Page 9: ...78 0013 1813 4 A 9 ...

Page 10: ...ranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s...

Reviews: