78-0013-1813-4-A

1.0  General

The 3M

 Indoor Protected Building Entrance Terminal (IBET) 4588V-QCS Series provides electrical protection 

and a termination point for outside plant cable (feeder) and indoor house wiring (distribution). The 4588V-QCS 

IBET is Underwriters Laboratories (UL 348X) Listed.

1.1  4588 Series IBET Names, Pair Capacity and Module

4588QCS-HCCA/25SD

25-pair HiCat Indoor Building Entrance Terminal with 710 SD

4588QCS-HCCA/50SD

50-pair HiCat Indoor Building Entrance Terminal with 710 SD

4588QCS-HCCA/100SD

100-pair HiCat Indoor Building Entrance Terminal with 710 SD

1.2  IBET Parts and Components

a) 

 Connectorized tails with 3M flame-retardant 
modules. 3M

 MS²

 Super Mini Splicing 

Module 4000-D/CO, 3M

 MS²

 Fire Retardant 

Pluggable Module 4005-DPM/FR or 3M

 710 

Splicing System SD modules.

b) 

Splice chamber, for the feeder cable, with 
cable strain relief. (Note diagram)

c) 

Insulated #6 ground strap for the feeder 
cable.

d) 

External bottom-mounted three point ground 
bar and top-mounted single point ground 
bar. (Note diagram)

e) 

Numbered standard 5-pin protector 
receptacle field. (Note diagram)

f) 

Binding post log and instruction label.

g) 

The 3M

 Single Pair Test Probe and Dish.

h) 

Fully lockable protective cover.

i) 

Three (3) screws (2 small and 1 large) 
to wall mount the IBET Terminal. (Note 
diagram)

4588 QCS-50

1.3  IBET Dimensions and Wiring Schematic

Model

Height

Width

Depth

4588QCS-25

12.46

12.47

4.83

4588QCS-50

12.46

12.47

4.83

 

Module

From C.O.

Protector

2810 Block

26 AWG Fuse Wire

4588V-QCS Wiring Schematic

1.4  Protector Specifications 

Use ONLY UL Recognized or Listed five-pin 
protectors in the 4588V-QCS terminal.

1.5  Special Tools Needed to Install 

3M

 

MS

2

 modules or 3M

 

710 connectors (Not 

required if 3M

  

Scotchlok

 Connectors are used)

Summary of Contents for 4588QCS-HCCA/100SD

Page 1: ...Indoor Protected Building Entrance Terminal 4588V QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories UL 348X Listed April 2010 78 0013 1813 4 A 3 ...

Page 2: ...10 Splicing System SD modules b Splice chamber for the feeder cable with cable strain relief Note diagram c Insulated 6 ground strap for the feeder cable d External bottom mounted three point ground bar and top mounted single point ground bar Note diagram e Numbered standard 5 pin protector receptacle field Note diagram f Binding post log and instruction label g The 3M Single Pair Test Probe and D...

Page 3: ...rt stub insulated ground wire and accessories out of the splicing chamber 2 4 Mount the terminal in designated position with the three mounting screws provided 2 5 Remove the jumper wire retaining ring from poly bag and install in faceplate 3 0 Feeder Cable Preparation and Strain Relief 3 1 Feeder cable diameters for the 3M Indoor Building Entrance Terminal IBET 4588V QCS Series PET Pair Count Fee...

Page 4: ...te Failure to properly bond and ground the terminal per N E C or local equivalent codes may render protection arrestors useless 4 2 Module splicing Splice per your company practice 4 3 Splice the feeder cable groups to the corresponding connectorized stubs according to your company s practice 4 4 3M Scotchlok Connector or individual connector splicing 4 5 Splice the feeder cable groups to the corr...

Page 5: ... least 5 cm 2 in of slack 6 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3 1 and 3 2 6 5 Terminate additional jumper wires by repeating the above procedure 6 6 To remove jumper wires open the cap and pull the wires straight out from block 6 7 Route the wire below the connected cap 7 0 Installing the Electrical Protectors Note Use ONLY UL Recog...

Page 6: ... cover closed the exposed hasp allows for locking when security is required 9 0 3M Single Pair Test Probe 2827 9 1 Testing using 3M Single Pair Test Probe 2827 9 2 Plug the test probe into the cap of the pair being tested with the black lead to the left and the red lead to the right 10 0 3M Priority Caps 10 1 Priority Caps are used to designate special purpose circuits and prevent entry of the 3M ...

Page 7: ...tack the IBET terminal vertically up to three of the same cable pair count and within the diameter limits in the chart in 3 01 11 2 Mounting the IBET terminal a Mount the IBET terminal bodies using the cable glands to position them b Assemble the feeder cable strain relief according to Section 3 0 and prepare the feeder cable so that 21 of free conductor length will be in the last IBET terminal 1 ...

Page 8: ...8 78 0013 1813 4 A ...

Page 9: ...78 0013 1813 4 A 9 ...

Page 10: ...ranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s...

Reviews: