3-104
Issue 5
May 1997
363-208-010
Cabling, Wiring, and Assembly
4TEL RMU Control Link Cable ED7C723-34 Group 9
This cable is the control link with the
RMU. Refer to Figure 5-8 in Chapter 5 for its
wiring details.
Step 1:
Mate the SWITCH/DLC connector of the cable assembly to its associ-
ated connector on the
RMU.
Step 2:
Mate the cable's P44 connector to the J44 connector of the ARM shelf
dangler cable ED7C723-30 Group 17 installed earlier.
DC Test Pair Cable ED7C723-35 Group 11
This cable assembly, containing a test access pair, 2 VF pairs, and a frame ground
termination is connected to the Misc. Pairs Cross-connect block.
Step 1:
Mate the cable's J1 connector with the
RMU's P1 connector.
Step 2:
Terminate and label the leads in accordance with the associated figure
for J1 in this section.
Figure 3-55. 4TEL RMU Power Connections (ED7C723-34, Group 10)
R
BK
1
6
5
9
Wiring Side
-48v
RTN
J2
R
-48v
BK
RTN