A-22
Issue 5
May 1997
363-208-010
Applications
Figure A-8B. Power and Ringing Cabling (J1C182BD-1)
p/o
ED7C734-30
Power Interface Unit
TB1
-48V A
A RTN
-48V B
B RTN
P, 14ga
1
2
3
4
p/o Ringing Shelf
e/w 2 Ringing Supplies
J1C182BD-1 or equivalent
J100
-20Hz A
20Hz RTN
+20Hz A
-20Hz B
20Hz RTN
+20Hz B
5
6
7
8
9
10
1
3
7
-48V2
48R1
48R2
-48V1
13
15
FRQ
MJ
PMN
MN
20HzR
-20Hz1
+20Hz1
-20Hz2
+20Hz2
P100
4
10
12
Refer to RT Input Alarms
Applications Figure A-7
20 ga
24 ga
P140
Battery
Connections