VLAN ID -
VLAN identifier. Each tag-based VLAN group has a unique VID.
It appears only in tag-based and Double-tag mode.
IGMP Proxy
- IGMP proxy enables the switch to issue IGMP host
messages on behalf of hosts that the system discovered through
standard IGMP interfaces. The system acts as a proxy for its hosts.
This switch can be set IGMP function ―Enable‖ or ―Disable‖ by VLAN
group. If the VLAN group IGMP proxy is disabled, the switch will
stop the exchange of IGMP messages in the VLAN group members.
If the VLAN group IGMP proxy is enabled, the switch will support
the exchange of IGMP messages in the VLAN group members and
follow up IGMP proxy router port configuration, which connects to a
router closer to the root of the tree. This interface is the upstream
interface. The router on the upstream interface should be running
IGMP. You enable IGMP on the interfaces that connect the system
to its hosts that are farther away from the root of the tree. These
interfaces are known as downstream interfaces.
Member Port -
This is used to enable or disable if a port is a
member of the new added VLAN, ―Enable‖ means it is a member of
the VLAN. Just tick the check box (
) beside the port x to enable it.
Add new VLAN -
Please click on <
Add new VLAN
> to create a
new Tag-based VLAN. Input the VLAN name as well as VID,
configure the SYM-VLAN function and choose the member by ticking
the check box beside the port No., then, press the <
Apply
> button
to have the setting taken effect.
Delete Group -
Just press the <
Delete
> button to delete the
selected exist group entry from the Tag-based group table.
N
OTE
:
If you need use PVLAN( Private VLAN) function on Switch
then you need follow up the process as below:
a.
Create a VLAN as primary VLAN and the VLAN ID is 2 and evoke the
Private VLAN to enable Private VLAN service.
b.
Assign port member to the VLAN2
c.
You need to assign these ports for member of port isolation.
d.
Press the “Save” to complete the PVLAN configuration process
Summary of Contents for LGS-2816C-RPS
Page 4: ...Revision History Release Date Revision 5 17 01 10 2010 B1...
Page 5: ...CONTENTS...
Page 56: ...74 CHAPTER 4 Configuring the Switch Configuring Power Saving the manufacturer...
Page 69: ......
Page 117: ...Figure 4 50 Access Control List Configuration...
Page 154: ...172 CHAPTER 4 Configuring the Switch Configure SNMP designated port of the root bridge...
Page 162: ...180 CHAPTER 4 Configuring the Switch Configure SNMP...
Page 196: ...346 CHAPTER 8 Commands of CLI Alarm Commandsof CLI...
Page 199: ...346 CHAPTER 8 Commands of CLI Alarm Commandsof CLI...
Page 207: ...3 Click Upload Figure 110 Display Firmware Upgrade Screen...
Page 241: ...349 Interfaces Evolution MIB RFC 2863 IP MIB RFC 2011...