Safety
29
Pos: 16.7 /Überschriften/Überschriften 3/K-O/O/Ölstandskontr olle, Öl- und Filterel ementwechsel sicher durchführen @ 464\mod_1466749860961_78.docx @ 3128448 @ 3 @ 1
3.5.3
Safely checking the oil level and changing the oil and filter element
Pos: 16.8 /BA/Sicher heit/3. Sicherheitsr outinen/Ölstandskontr olle, Öl- und Filterel ementwechsel sic her durchführen @ 492\mod_1487079943575_78.docx @ 3312286 @ @ 1
WARNING!
Perform oil level check, oil change and filter element change safely!
If oil level check, oil change and filter element change are not performed safely, the
operational safety of the machine may be affected. This may result in accidents.
• Perform oil level check, oil change and filter element change safely.
In order to perform oil level check, oil change and filter element change safely:
• Lower raised machine parts or secure them against falling, refer to chapter Safety,
“Securely Supporting Raised Machine and Machine Parts”.
• Shut down and safeguard the machine, refer to chapter Safety, “Shutting Down and
Safeguarding the Machine”.
• Observe the intervals for oil level check, oil change and filter element change, refer to
chapter Maintenance, “Maintenance Table”.
• Use only oil qualities/quantities mentioned in the consumables table, refer to chapter
Technical Data, “Consumables”.
• Clean the area around the parts (for example gearbox, high-pressure filter) and make sure
that foreign bodies do not get into the parts or the hydraulic system.
• Check existing seal rings for damage and replace them, if necessary.
• Collect escaping oil or waste oil in a container provided for that purpose and dispose of it
properly, refer to chapter Safety, “Consumables”.
Pos: 16.9 /Überschriften/Überschriften 3/A-E/A/Aktortest durchführ en @ 476\mod_1473324458676_78.docx @ 3215342 @ 3 @ 1
3.5.4
Running the actuator test
Pos: 16.10 /BA/Sicherheit/3. Sicher hei tsrouti nen/Aktortest durchführen @ 476\mod_1473324580783_78.docx @ 3215382 @ @ 1
WARNING!
Run actuator test safely
When actuators are energised, functions are carried out directly and without a safety prompt.
This may cause the unintentional movement of machine parts, trapping and seriously or fatally
injuring persons.
– Only persons familiar with the machine are permitted to perform the actuator test.
– The person performing the test must know which machine parts are activated by
controlling the actuators.
• Run the actuator test safely.
To run the actuator test safely:
• Lower or securely support the raised machine parts, see chapter Safety "Securely
supporting the raised machine and machine parts".
• Shut down and safeguard the machine, see chapter Safety, "Shutting down and
safeguarding the machine".
• Cordon off the danger zone of the actuated moving machine parts in a clearly visible
manner.
• Ensure that there is nobody in the danger zone of the actuated moving machine parts.
• Switch on the ignition.
• Run the actuator test only from a safe position outside the area which is affected by
machine parts moved by the actuators.
Pos: 17 /Layout M odul e /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1