Maintenance
253
Pos: 52.141.18 /Überschriften/Überschriften 3/A-E/D/Druckluftbehäl ter @ 34\mod_1255593348281_78.docx @ 324372 @ 3 @ 1
13.24.3
Compressed-air reservoir
Pos: 52.141.19 /BA/Wartung/Druckluftbehäl ter/Dr uckl uftbehälter Bild CF/C V @ 76\mod_1310031671148_78.docx @ 666415 @ @ 1
CP102170
1
2
Fig. 221
Pos: 52.141.20 /BA/Wartung/Druckluftbehäl ter/Dr uckl uftbehälter _T ext_mit Pos @ 76\mod_1310032535881_78.docx @ 666447 @ @ 1
The compressed air reservoir (1) stores the compressed air that is pumped by the compressor.
Therefore condensation water may settle in the compressed air reservoir (1) during operation.
The compressed-air reservoir must be emptied regularly. Specifically, it must be emptied:
• daily in winter (when being used),
• otherwise weekly and
• at least after 20 operating hours.
The drain valve (2) on the bottom of the compressed air reservoir (1) is used for draining.
• Switch off and secure the machine
• Open the drain valve and allow the condensation to run out
• Check the drain valve, clean it and screw it back in
Note
If the drain valve has a heavy accumulation of dirt or is leaking, it must be replaced by a new
one.
Pos: 52.141.21 /BA/Sicherheit/2. Vorangestellte Warnhinweise/Warnung - Dr uckluftbehälter beschädigte oder korrodi ert - Alte F or m @ 275\mod_1404385710309_78.docx @ 2066945 @ @ 1
WARNING!
Risk of injury from corroded or damaged compressed air reservoirs.
Damaged or corroded compressed air reservoirs may burst and cause serious injuries.
• Observe the inspection intervals according to the maintenance table, see chapter
Maintenance Engine "Maintenance table".
• Have damaged or corroded compressed air reservoirs replaced immediately by a service
centre.