KRONE Operation Unit Alpha
102
Pos: 42.51 /Ü berschriften/Ü berschriften 3/A-E/A/Anzeigen der "Versionsnummer" @ 55\mod_1294753104812_78.docx @ 534210 @ 3 @ 1
8.2.2
Displays “Version Number”
Pos: 42.52 /WH B/Elektri k/R undballenpresse/Alpha (Medium) /Anzeigen der Versi onsnummer @ 83 \mod_1317109948175_78.docx @ 726835 @ @ 1
A B
C D
E F
G H
2
3
6
7
8
10
RPM00050
Fig. 76
• When switching operation on, keep the
key pressed.
The version number is displayed in the bar graph (11).
Pos: 42.53 /Ü berschriften/Ü berschriften 3/A-E/A/Akustische und optische Signale sowi e der en Bedeutung @ 55\mod_1294753278531_78.docx @ 534262 @ 3 @ 1
8.2.3
Acoustic and Visual Signals and their Meaning
Pos: 42.54 /WH B/Elektri k/R undballenpresse/Akustische und optische Signale sowi e deren Bedeutung @ 55\mod_1294753471984_78.docx @ 534314 @ @ 1
Acoustic
Visual
Bale chamber full
Net is injected
Wrapping complete
Net not tied
LED A on the bar
graph flashes briefly
Net stopped
LED C on the bar
graph flashes briefly
Net has not been cut
off
LED E on the bar
graph flashes briefly
New settings
required
Sensor error (cable
break)
Slip
LED H on the bar
graph flashes
continuously
Pos: 43 /Layout M odul e /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1