DCP 30 LX / DCP 30 SX
Issue: 11/2009
70
6 .2 .4 Cleaning the Heat Exchanger
• To reach the heat exchanger, remove the cover plate (Allen key 4 mm).
• The fins (arrow) of the air condenser should be cleaned weekly with a fine brush or a
vacuum cleaner.
ATTENTION
U
Do not bend the fins.
U
Do not touch them with your hands or sharp tools.
6 .3
Maintenance
DANGER
Always switch off the main switch (position
0 OFF
), before doing any cleaning or
maintenance work.
6 .3 .1 Changing the Xenon Bulb
DANGER
S
Xenon bulbs are high-pressure discharge lamps in which a high interior pressure
exists even if bulb is cold.
S
Inserting the xenon bulb wear safety gloves, face protection and protective suit.
S
Handle the xenon bulb with extreme care, never force it during installation.
S
Do not insert the xenon bulb by touching it on the glass bulb.
S
Install the xenon bulb in its protective coat only.