DCP 30 LX / DCP 30 SX
Issue: 11/2009
69
Cleaning / Maintenance
6 .2 .3 .2 Fans in the Lamphouse
• Remove the lamphouse outer cover
plates (Allen key 4 mm) to reach the
fans.
• Use a vacuum cleaner to remove
the loose dust on the blower impeller
of the two fans (arrows) and on the
inner cover plates.
• Close lamphouse again.
6 .2 .3 .3 Fans on the ELCA Box
• To clean the fans on the ELCA box,
remove the frontal cover plate on the
projector head (lens side).
• Use a brush with long bristles or a
vacuum cleaner to remove the loose
dust on the blower impeller of the
two fans (arrows).
• Close the housing again.