DCP 30 LX / DCP 30 SX
Issue: 11/2009
6
1 .5 .4 Lamphouse
Mechanical danger by broken glass flying around:
- when operating the xenon lamp
- when changing the xenon bulb
- when disposing of the xenon bulb
DANGER OF EXPLOSION
S
Never bypass the door switch.
S
Only work on open lamphouse and with xenon bulb with face protection (shield),
neck protection and safety gloves which reach to the elbow.
If the xenon lamp explodes you can suffer injury to face, eyes and arteries.
S
In cold condition the xenon lamp has an inner pressure of about 8 to 10 bar (145 psi)
and in hot condition of about 30 bar (435 psi).
S
Dispose xenon bulb: Before removing xenon lamp put protective cover around it,
pack xenon bulb in original package and give it back to your supplier.
S
Only insert the new xenon bulb in protective cover. Remove cover after mounting the
xenon bulb.
Danger because of ultraviolet radiation:
- when operating the xenon lamp with an open lamphouse
DANGER
Operate projector with a closed lamphouse only. If you do some adjustments with an
open lamphouse (look through visual hole), you have to use visual protection which
blocks the ultraviolet radiation.
Never look into light of a xenon lamp without
protective glasses!
Danger because of high voltage:
- when igniting the xenon lamp
DANGER
Ignite xenon lamp in closed lamphouse only.