The User Manual of JAC200 Series General Frequency Converter
- 25 -
Function
code
Name
Set range
Default
value
Chan
ge
F3-00
VF curve setting
0: Linear V/F 1: Multi-point V/F
2: Square V/F 3: 1.2
th
power V/F
4: 1.4
th
power V/F 6: 1.6
th
power V/F
8: 1.8
th
power V/F 9: Reserved
10: VF complete separation mode
11: VF semi-separation mode
0
★
F3-01
Torque boost
0.0%: (Automatic torque boost)
0.1%
~
30.0%
Model
dependent
☆
F3-02
Cut-off frequency of
torque boost
0.00Hz~ maximum frequency
50.00Hz
★
F3-03
Frequency Point 1 of
multi-point VF
0.00Hz
~
F3-05
0.00Hz
★
F3-04
Voltage Point 1 of
multi-point VF
0.0%
~
100.0%
0.0%
★
F3-05
Frequency Point 2 of
multi-point VF
F3-03
~
F3-07
0.00Hz
★
F3-06
Voltage Point 2 of
multi-point VF
0.0%
~
100.0%
0.0%
★
F3-07
Frequency Point 3 of
multi-point VF
F3-05 ~rated frequency of motor (F1-04)
0.00Hz
★
F3-08
Voltage Point 3 of
multi-point VF
0.0%
~
100.0%
0.0%
★
F3-09
VF slip
compensation gain
0.0%
~
200.0%
0.0%
☆
F3-10
VF overexcitation
gain
0
~
200
64
☆
F3-11
VF oscillation
suppression gain
0
~
100
Model
dependent
☆
F3-13
Voltage source of VF
separation
0: Digital setting (F3-14)
1: AI
2:
Reserved
3: Key
potentiometer
4: Reserved
5: Multi-stage instruction
6: Simple PLC
7: PID
8: Communication reference
Note: Correspond to the rated voltage of
motor in 100.0%
0
☆