Tens place
Function code read-write abnormity (Err21)
0
Free stop
1
Stop according to stop mode
Hundreds
place
Reserved
Thousands
place
Motor overheating (Err25) (The same as F9-47 ones
place)
Myriabit
Operation time arrival (Err26) (The same as F9-47
ones place)
F9-49
Select 3 for the failure protection
action
Default value
00000
Set range
Ones place
User-defined failure 1(Err27) (The same as F9-47 ones
place)
Tens place
User-defined failure 2(Err28) (The same as F9-47 ones
place)
Hundreds
place
Power-on time arrival (Err29) (The same as F9-47 ones
place)
Thousands
place
Off-load (Err30)
0
Free stop
1
Stop according to stop mode
2
Directly jumps to 7% of the rated frequency of a motor
and continues to operate, if there is no Off-load, it shall
return to the set frequency and operate automatically
Myriabit
The PID feedback is missing during operation
F9-50
Select 4 for the failure protection
action
Default value
00000
Set range
Ones place
Speed deviation is too large (Err42) (The same as F9-47
ones place)
Tens place
Motor supervelocity (Err43) (The same as F9-47
ones place)
Hundreds
place
Initial position error (Err51) (The same as F9-47 ones
place)
Thousands
place
Speed feedback error (Err52) (The same as F9-47 ones
place)
Myriabit
Reserved
When we select “free stop”, the frequency converter shall display Err**, and stop directly.