The User Manual of JAC200 Series General Frequency Converter
- 137 -
Set range
0
~
3
FC-44
Stage 13 running time of simple PLC
Default value
0.0s(h)
Set range
0.0s(h)
~
6553.5s(h)
FC-45
Stage 13 acceleration/ deceleration
time of simple PLC
Default value
0
Set range
0
~
3
FC-46
Stage 14 running time of simple PLC
Default value
0.0s(h)
Set range
0.0s(h)
~
6553.5s(h)
FC-47
Stage 14 acceleration/ deceleration
time of simple PLC
Default value
0
Set range
0
~
3
FC-48
Stage 15 running time of simple PLC
Default value
0.0s(h)
Set range
0.0s(h)
~
6553.5s(h)
FC-49
Stage 15 acceleration/ deceleration
time of simple PLC
Default value
0
Set range
0
~
3
FC-50
PID integral attribute
Default value
0
Set range
0
S (second)
1
h (hour)
FC-51
Given mode of multi-stage 0
Default value
0
Set range
0
Function code FC-00 reference
1
AI
2
Reserved
3
Key
potentiometer
4
Reserved
5
PID
6
Preset frequency (F0-08) reference, UP/DOWN (can be
modified)
The parameter determines the given channel of multi-stage Index 0.
Except FC-00, multi-stage can select others and it is convenient to switch between short indexes and other
given modes.
If multi-stage or simple PLC is used as frequency source, it is convenient to realize the switch between two
frequency sources.
Group FD Communication parameter
See JAC200 Communication Protocol.