The User Manual of JAC200 Series General Frequency Converter
- 60 -
Upper computer gives the operation command through communication mode. See appendix 1 for definition
of control command: JAC200 address defines the supplementary description of communication card.
F0-03
Principle
frequency source
X Selection
Default value
4
Set range
0
Digital Setting (The preset frequency is F0-08, the UP/DOWN can be
modified, no power-down memory)
1
Digital Setting (The preset frequency is F0-08, the UP/DOWN can be
modified, power-down memory)
2
AI
3
Reserved
4
Key potentiometer
5
Reserved
6
Multi-stage instruction
7
PLC
8
PID
9
Communication reference
Choose the input channel of the
main given frequency of frequency converter. There are a total of 10 main
given frequency channels.
0: Digital Setting ( No power-down memory)
Set the initial value at the value of F0-08 "preset frequency ”. It can change the set frequency value of the
frequency converter through the key▲ and the key▼ on the keyboard (or the UP and DOWN of
multi-function input terminals)
When power on again after the power down of the frequency converter, the set frequency value
reverts to
the value of F0-08 “digital setting preset frequencies”
1: Digital Setting (power-down memory)
Set the initial value at the value of F0-08 “preset frequency”. It can change the set frequency value of the
frequency converter through the key▲ and the key▼ on the keyboard (or the UP and DOWN of
multi-function input terminals)
When power on again after the power down of the frequency converter, the set frequency value is the last
time preset frequency at the time of power-down. It was memorized by the
calibration amount of the key▲
and the key▼ on the keyboard or the UP and DOWN terminals.
What need to be reminded is that F0-23 is “the selection of shutdown memory for digital set frequency” and