The User Manual of JAC200 Series General Frequency Converter
- 38 -
Function
code
Name
Set range
Default
value
Chan
ge
arriving current 2
motor
)
F8-42
The selection of
timing function
0: Invalid 1: Valid
0
☆
F8-43
The selection of
timing running time
0: F8-44 setting
1
:
AI
2
:
Reserved
3
:
Key
potentiometer
The range of analog input is corresponding
to F8-44
☆
F8-44
Timing run time
0.0Min
~
6500.0Min
0.0Min
☆
F8-45
The lower limit
protection value of
AI input voltage
0.00V
~
F8-46
3.10V
☆
F8-46
The upper
limitingprotection
value of AI input
voltage
F8-45
~
10.00V
6.80V
☆
F8-47
The arriving of
modules temperature
0
℃~
100
℃
75
℃
☆
F8-48
cooling fan
0: The fan is operating when at the run time
1: The fan is operating all the time
0
☆
F8-49
Wakening frequency
Dormant frequency (F8-51)
~
Maximum
frequency (F0-10)
0.00Hz
☆
F8-50
The waking delay
time
0.0s
~
6500.0s
0.0s
☆
F8-51
Dormant frequency
0.00Hz
~
Wakening frequency (F8-49)
0.00Hz
☆
F8-52
Ten dormant delay
time
0.0s
~
6500.0s
0.0s
☆
F8-53
The arriving time
setting for the run
0.0 ~6500.0 minutes
0.0Min
☆
F8-54
The carlibration
coefficient of output
power
0.00%
~
200.0%
100.0%
☆
Group F9 Failure and protection
F9-00
The protection
selection of motor
overloading
0: Forbidden
1: Permited
1
☆
F9-01
The protection gain
of motor overloading
0.20
~
10.00
1.00
☆