The User Manual of JAC200 Series General Frequency Converter
- 106 -
If above parameters must be displayed in operation, the corresponding
position shall be set as 1. The binary number shall be converted to
hexadecimal number and then be set to F7-04.
Displayed parameters in operation shall be used to set the parameters that can be checked when the
frequency converter is in operation.
The quantity of state parameters that can be checked at most is 32. The state parameters to be displayed
shall be selected according to the binary bit of F7-03 and each F7-04 parameter value. The display order
shall start from lowest bit of
F7-03
.
F7-05
Displayed LED parameters in stop state.
Default value
33
Set
range
0000
~
FFFF
If above parameters must be displayed in stop state, the corresponding
position shall be set as 1. The binary number shall be converted to
hexadecimal number and then be set to F7-05.
F7-06
Displayed load speed parameter
Default value
1.0000
Set range
0.0001
~
6.5000
The corresponding relation between the output frequency of frequency converter and load speed shall be
adjusted through the parameter when the load speed must be displayed. See the description for F7-12 for
specific corresponding relation.
F7-07
Inverter module radiator
temperature
Default value
-