The User Manual of JAC200 Series General Frequency Converter
- 57 -
Function
code
Name
The minimum
unit
Address
U0-05
Output power (kW)
0.1kW
7005H
U0-06
Output torque (%)
0.1%
7006H
U0-07
DI Input state
1
7007H
U0-08
DO Output state
1
7008H
U0-09
AI Voltage (V)
0.01V
7009H
U0-10
Reserved
0.01V/0.01mA
700AH
U0-12
Count value
1
700CH
U0-13
Length value
1
700DH
U0-14
Display of loading speed
1
700EH
U0-15
PID Setting
1
700FH
U0-16
PID Feedback
1
7010H
U0-17
Stage PLC
1
7011H
U0-18
Reserved
0.01kHz
7012H
U0-19
Feedback speed (Hz)
0.01Hz
7013H
U0-20
The remaining run time
0.1Min
7014H
U0-21
AI Voltage before calibration
0.001V
7015H
U0-22
Reserved
0.001V/0.01Ma
7016H
U0-24
Linear speed
1m/Min
7018H
U0-25
The current power-on time
1Min
7019H
U0-26
The current run time
0.1Min
701AH
U0-28
Set value of communication
0.01%
701CH
U0-29
Feedback speed of encoder
0.01Hz
701DH
U0-30
Principal frequency
0.01Hz
701EH
U0-31
Auxiliary frequency Y Display
0.01Hz
701FH
U0-32
Examine the address value of arbitrary memory
1
7020H
U0-35
Target torque (%)
0.1%
7023H
U0-37
Angle of power factor
0.1°
7025H
U0-38
ABZ Position
1
7026H
U0-39
Voltage of VF separation target
1V
7027H
U0-40
Voltage of VF separation output
1V
7028H
U0-41
Visual display in DI input state
1
7029H
U0-42
Visual display in DO input state
1
702AH