The User Manual of JAC200 Series General Frequency Converter
- 114 -
Fig. 6-19 is acceleration/deceleration time switching diagram. During acceleration, if operation frequency is
less than F8-25, then acceleration time 2 shall be selected; if operation frequency is greater than F8-25, then
acceleration time 1 shall be selected.
During deceleration, if operation frequency is greater than F8-26, then acceleration time 1 shall be selected;
If operation frequency is less than F8-26, then acceleration time 1 shall be selected.
F8-27
Terminal jog priority
Default value
0
Set range
0: Invalid; 1: Valid
The parameter is used to set whether the priority level of terminal jog function is the highest.
When the jog priority of the terminal is valid, if terminal jog command appears in operation, the frequency
converter shall be switched to jog running state.
F8-28
Frequency test value (FDT2)
Default value
50.00Hz
Set range
0.00Hz
~
Maximum frequency
F8-29
Lagged frequency test value
(FDT2)
Default value
5.0%
Set range
0.0%
~
100.0% (FDT2 level)
The frequency test function and FDT1 function are identical; please see FDT1 description, i.e. the
description for Function code F8-19 and F8-20.
F8-30
Arbitrarily arriving frequency test
value 1 1
Default value
50.00Hz
Set range
0.00Hz
~
Maximum frequency
F8-31
Arbitrarily arriving frequency
detected width 1
Default value
0.0%
Set range
0.0%
~
100.0% (Maximum frequency)
F8-32
Arbitrarily arriving frequency test
value 2
Default value
50.00Hz
Set range
0.00Hz
~
Maximum frequency
F8-33
Arbitrarily arriving frequency
detected width 2
Default value
0.0%
Set range
0.0%
~
100.0% (Maximum frequency)
When the output frequency of the frequency converter in within positive/negative detected range of
arbitrarily arriving frequency, multifunctional DO shall output ON signal. JAC200 provides two groups of
arbitrarily arriving frequency detected width and sets frequency value and frequency test range separately.
Fig. 6-20 is the function diagram.