The User Manual of JAC200 Series General Frequency Converter
- 46 -
Function
code
Name
Set range
Default
value
Chan
ge
FA-02
PID feedback source
0: AI
1: Reserved
2: Key
potentiometer
3: Reserved
4: Reserved
5:
Communication reference
6: Reserved
7: Reserved
8: Reserved
0
☆
FA-03
PID action direction
0: Positive action
1: Negtive action
0
☆
FA-04
PID given feedback
range
0
~
65535
1000
☆
FA-05
Proportional gain
Kp1
0.0
~
100.0
20.0
☆
FA-06
Integral time Ti1
0.01s
~
10.00s
2.00s
☆
FA-07
Differential time Td1
0.000s
~
10.000s
0.000s
☆
FA-08
The reversal cut-off
frequency of PID
0.00
~
Maximum frequency
2.00Hz
☆
FA-09
PID deviation limit
0.0%
~
100.0%
0.0%
☆
FA-10
PID differential
amplitude limiting
0.00%
~
100.00%
0.10%
☆
FA-11
Given changed
time of PID
0.00
~
650.00s
0.00s
☆
FA-12
Filtering time of PID
feedback
0.00
~
60.00s
0.00s
☆
FA-13
Filtering time of PID
output
0.00
~
60.00s
0.00s
☆
FA-15
Proportional gain
Kp2
0.0
~
100.0
20.0
☆
FA-16
Integral time Ti2
0.01s
~
10.00s
2.00s
☆
FA-17
Differential time Td2
0.000s
~
10.000s
0.000s
☆
FA-18
Switching conditions
of PID parameters
0: Not switched
1: Switch through DI terminal
2: According to the deviation to switch
automaticaly
0
☆
FA-19
Switching deviation1
of PID parameter
0.0%
~
FA-20
20.0%
☆
FA-20
Switching deviation2
of PID parameter
FA-19
~
100.0%
80.0%
☆