Maintenance
XHD Installation, Operation, and Maintenance Manual
90
1. Remove the two-piece suction and discharge flanges (195C, XHD sizes 150 and above
only).
Figure 72: Joint gaskets and flanges removal
Remove the suction half casing - Rubber-Lined
The following parts remain attached to the suction half casing when it is removed from the rest
of the pump wet end:
Model
Parts that are still attached
XHD Rubber-lined single piece suction liner
• Suction side liner (600R)
• Hardware Hex head bolts/hex cap screws
1. Support the suction half casing (100A) with a hoist hook through the lifting lug. Tension the
hoist properly so the sub-assembly will be fully supported upon disengagement.
2. Remove the casing hex head nuts (600C) and flat washers (553) from the casing hex head
bolts (600A) and tapered alignment studs (600D).
3. Leave the tapered alignment studs (600D) secured in place. The studs will provide
guidance in removal of the sub-assembly.
4. Guide the suction half casing (100A, with attached components) free of tapered alignment
studs.
Figure 73: Gland and suction liner